Rish Master 3440i Multifunction Meter, 10~ 120% Of Rated Value

Brochure


Feature:

Model Name/Number Rish Master 3440i
Voltage 10~ 120% of rated value
Relative Humidity 0~90% non condensing
Brand Rishabh
Temperature coefficient 0.025%/ Degree C - Voltage (50~ 120% of rated value)
Response time to step input 1 sec approx.
Current Range 10~100% of Nominal Value.
Auxiliary supply voltage Rated Value +-1%
Input frequency 50 Hz +-2%
Pollution degree 2
Voltage Range 50~100% of Nominal Value.
High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all electrical circuits
Vibration 10~ 55 Hz, 0.15mm amplitude
Enclosure IP54 (front face only)
Shock 15g in 3 planes
Warm up time Minimum 3 minute
Operating temperature -10 to +55 Degree C
Storage temperature -20 to +65 Degree C
Reference temperature 23 +/- 2 Degree C
Frequency 40~70 Hz
System CT secondary values 1A programmable on site.
System CT primary values From 1A * (for 1 or 5 Amp )
Nominal input current 1A / 5A AC RMS.
Max continuous input voltage 120% of rated value
Nominal input voltage (AC RMS) Phase -Neutral 57.7 - 346 VL-N,Line-Line 100 - 600 VL-L
System PT primary values 100VLL programmable on site
Max continuous input current 120% of rated value
AC /DC Auxiliary Supply 60 VAC /DC OR 12 - 60 VAC /DC
Auxillary Supply burden < 6.5 VA approx.
Current 5 ~ 120% of rated value
Nominal input current burden <0.3 VA approx. per phase
Nominal input voltage burden < 0.35 VA approx. per phase
AC Auxiliary supply frequency range 45 hz
Power Factor 0.5 Lag ~ 1~0.8 Lead




Description:

Rish Master 3440i Multifunction Meter, 10~ 120% Of Rated Value:

RISH Master 3440i measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy (Active/ Reactive/Apparent), Harmonic Distortion. The instrument has optional output as one pulse output or two pulse output for energy measurement.


User selectable CT Secondary 5A/1A
The secondary of external Current Transformer (CT) can be programmed on site to either 5A or 1A locally by entering into Programming mode or remotely via MODBUS (Rs485) 

User selectable PT Secondary
The secondary of external potential Transformer (PT) can be programmed on  site  locally  by  entering  into  programming  mode  or  remotely  via MODBUS (RS485) 
User selectable 3 phase 3W or 4W unbalanced network
User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire locally    by entering into Programming mode or remotely via MODBUS (RS485). For single phase applications,  single phase version is available. 

Low back depth
The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output 

Features:

Rish Master 3440i Multifunction Meter, 10~ 120% Of Rated Value:

Model Name/Number Rish Master 3440i
Voltage 10~ 120% of rated value
Relative Humidity 0~90% non condensing
Brand Rishabh
Temperature coefficient 0.025%/ Degree C - Voltage (50~ 120% of rated value)
Response time to step input 1 sec approx.
Current Range 10~100% of Nominal Value.
Auxiliary supply voltage Rated Value +-1%
Input frequency 50 Hz +-2%
Pollution degree 2
Voltage Range 50~100% of Nominal Value.
High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all electrical circuits
Vibration 10~ 55 Hz, 0.15mm amplitude
Enclosure IP54 (front face only)
Shock 15g in 3 planes
Warm up time Minimum 3 minute
Operating temperature -10 to +55 Degree C
Storage temperature -20 to +65 Degree C
Reference temperature 23 +/- 2 Degree C
Frequency 40~70 Hz
System CT secondary values 1A programmable on site.
System CT primary values From 1A * (for 1 or 5 Amp )
Nominal input current 1A / 5A AC RMS.
Max continuous input voltage 120% of rated value
Nominal input voltage (AC RMS) Phase -Neutral 57.7 - 346 VL-N,Line-Line 100 - 600 VL-L
System PT primary values 100VLL programmable on site
Max continuous input current 120% of rated value
AC /DC Auxiliary Supply 60 VAC /DC OR 12 - 60 VAC /DC
Auxillary Supply burden < 6.5 VA approx.
Current 5 ~ 120% of rated value
Nominal input current burden <0.3 VA approx. per phase
Nominal input voltage burden < 0.35 VA approx. per phase
AC Auxiliary supply frequency range 45 hz
Power Factor 0.5 Lag ~ 1~0.8 Lead