Continuous Emissions Monitoring Systems (OCEMS), For Industrial Use

765500 incl. GST

Applied Techno Systems is Inginiuos manufacturer of Continuous Emission Monitoring Systems which includes Gas ANalyser, Gas Sampling Systems, Tempreture , flow & Opacity dust Monitoring Systems with real time data transmission Systems to CPCB & SPCB.
Applied Continuous Emission Montoring CEMS fullfill the environmental regulatory compliance of various industrieal sources of air pollutant.

Features:

  • Microcontroller based embedded intelligent instruments
  • Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2
  • Duel wavelength Infra red sensor for Long terms accuracy and stability
  • Long Life Electrochemical sensor
  • Six Gas Analysis in Single Analyser
  • Multi Parameter Single 320 X 240 Graphics LCD Display
  • Self diagnostic & Self integrity check
  • RS 232/RS 485 and USB Computer Interface
  • Excellent low level capability for NOX and SO2 Measurement
  • For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
  • Analog 4-20mA output for each gas
  • Software solutions for Gas Analysis
  • Web Based Real time data transfer

Feature
Application Industrial Use
Brand Applied Techno Systems
Gas Measurement O2,CO,CO2,NO,NO2,HF and Many More
Temperature Range -5 to 55 Deg C
Response Time less than 30 seconds at 95% variation
output 4-20mA
power supply 230 V AC
Display LCD Graphic Display
Analog Output 4-20mA
Accuracy +-1%
Digital Output USB RS-232,RS-485,MODBUS
Humidity 95% RH
Description

Applied Techno Systems is Inginiuos manufacturer of Continuous Emission Monitoring Systems which includes Gas ANalyser, Gas Sampling Systems, Tempreture , flow & Opacity dust Monitoring Systems with real time data transmission Systems to CPCB & SPCB.
Applied Continuous Emission Montoring CEMS fullfill the environmental regulatory compliance of various industrieal sources of air pollutant.

Features:

  • Microcontroller based embedded intelligent instruments
  • Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2
  • Duel wavelength Infra red sensor for Long terms accuracy and stability
  • Long Life Electrochemical sensor
  • Six Gas Analysis in Single Analyser
  • Multi Parameter Single 320 X 240 Graphics LCD Display
  • Self diagnostic & Self integrity check
  • RS 232/RS 485 and USB Computer Interface
  • Excellent low level capability for NOX and SO2 Measurement
  • For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
  • Analog 4-20mA output for each gas
  • Software solutions for Gas Analysis
  • Web Based Real time data transfer
Related Products
Bargraph Digital Indicator

DESCRIPTION:-

LTRON-101-1B and 2B are part of Lectrotek’s LTRON-series of Universal Indicators which includes 51- and 101-segment LED Digital Bargraph Indicators products.
The instruments come in DC 4-20mA and Universal site programmable inputs versions and accept RTDs, thermocouples J.K.R.S type, 4-20 mA and 1-5V DC signal inputs.

The indicators display information in form of a LED bargraph as well as digital modes. The bargraph a analogous display for easy operation understanding at a glance, especially in high density instrumentation panels, while its 4-digit display displays the exact values in settable ranges for precise display from a close view.

Applications are general-purpose process indication in control rooms where array of digital indicators may cause distraction/confusion, whereas, bargraph indicators give an approximate indication to operator for quick information and decision making.

They are handy to replace obsolete drum or pointer scale indicators and offer advantages of universal input programmability, dual displays for comprehensive operator information,The instruments have alarm options, wherein limits can be set on process input High (exceed) or Low (fall below PV) and operate relays for alarm and/or trip functions. 2 relays per channel are available, with adjustable limit hysterisis and potential-free C/O contacts.

4-20 mA isolated retransmission signal proportional to the input signal is available as option.

Isolated RS-485 serial port is also optional, with communication as per Modbus-RTU protocol.

LTRON-2B-101 are housed in ¼ DIN-size panel mounting enclosure of bezel size 72 x 144 mm, for both Dual Loop and Single Loop versions. They mount on panel fronts through cutouts of 68x 138mm, and are fixed with 2-clamps supplied.
NOTE:-

  • Single Loop Bargraph LTRON-1B-101 in bezel size 36x144 mm.
  • Dual Loop Bargraph in Slim size 36x144 mm with 4-20mA input and 24VDC powered
  • Circular Bargraph Indicators BRG-150.

SPECIFICATION:-

Inputs/ranges Fixed mA/VDC inputs are standard. Universal site programmable as per following input/range table  Input Type Range limitsDC inputs
4-20 mA DC Programmable range, decimals -1999 to +99991-5 V DC Programmable range, decimals -1999 to +9999Universal input typePt-100 RTD DIN-43760 -200 to + 600 ºCFe-Const T/C ANSI type J 0-600 ºCCr-Al T/C ANSI type K 0-1200 ºCPt-Pt-Rh13% ANSI type R 0-1600 ºCPt-Pt-Rh10% ANSI type S 0-1600 ºC

Others Available on request Consult us Accuracy (digital display) +/- 0.1% +/- 1 digit for DC and RTD inputs, 0.25% FS wc for thermocouple inputs Display 7-segments red LEDs, 4-digits and 101-segment red LEDs (bargraph).

  • Green bargraphs option User interface 4-key membrane keyboard for operation, configuration, calibration.
  • Setpoints 2 alarm linits programmable High or Low type per channel, with relay output.
  • Relays (option) 2 nos. (2 nos. per channel in dual loop), with C/O contacts, 7A, 240V resistive.
  • Retransmission option 4-20 mA isolated output proportional to input, load 500 ohms max.
  • RS-485 port option serial port with Modbus-RTU communication protocol.
  • Power Supply 100-265 VAC Power consumption 10VA max. (24VDC powered versions are an option).
  • Wiring Screwed terminals, max. 1.5 mm wire size, instrument back.
  • Enclosure ABS enclosure, suitable for panel mounting (IP 54 front, IP 40 rear).
  • Environmental Ambient temperature 50 ºC, 90% RH maximum, non-condensing
...